GAS & FLAME products
Teledyne Gas Measurement Instruments
Detecting the Difference
다양한 산업분야에 적용 가능 하도록 디자인된 가스 검출기 , 제어시스템 ,무선기술을 바탕으로 한 가스 검출기 등의 제품들을오래도록 축적된 경험을 바탕으로 제공해드리고 있습니다.
PS200
Introduction
A robust and accurate portable gas detector, the Personal Surveyor (PS200 Series) provides unrivalled protection in confined space applications with audible and visual alarms in the event of exposure to flammable or toxic gases.
Detecting and displaying up to 4 gases simultaneously, PS200 is suitable for a host of applications in a variety of industries. The PS200 can be configured to detect a combination of Methane, Oxygen, Carbon Monoxide, Hydrogen Sulphide, as well as other flammable gases.
Pre-entry checking can be carried out with the optional internal sampling pump, and diffusion operation ensuring maximum battery life in confined spaces.
Specifications
Measuring Ranges
LEL | 0 – 100% | |
O2 | 0 – 25% | |
CO | 0 – 1000ppm | |
H2S | 0 – 100ppm |
Certification
IEC | Ex ia d IIC T4 Gb |
ATEX | Ex II 2G Ex ia IIC T4 Gb |
CSA | Class I Div 1 Groups ABCD T4, Class 1 Zone 1 Ex ia d IIC T4 |
MED | (0038/YY) Modules B & E, A.1/3.30 |
CE |
Alarms
Highly visible flashing LED
Ultra loud audible alarm, 95dBA
Vibrations
Physical Properties
Dimensions:
121 (H) x 59 (W) x 32 (D) mm
Weight:
230g (with pump)
215g (without pump)
Environment
Humidity:
0 – 95% RH non-condensing
Temperature:
-20oC to +50oC (4oF to +122oF)
Power Supply
Lithium Ion rechargeable battery
Run Time (diffusion): > 14 hours
Run Time (pumped): > 8 hours
Charging Time: less than 4 hours
IP Rating
IP67Drop Test
3m / 10ftWarranty
2 years as standardPS500
Introduction
The PS500 can be tailored to detect up to five gases with its toxic and catalytic sensors, photo ionisation detectors and infrared capabilities. ‘Plug and Play’ option allows the customer to ‘plug in’ a new board with a different gas range.
The PS500 is particularly useful in noisy environments, featuring a very loud (95dBA) penetrating and distinctive audible alarm together with high visibility large area visual alarm. Pump, diffusion or both together, allowing pumped sample for pre-entry checking and diffusion in confined space working, thus maximising battery life. A robust, moulded, rubberised casing guaranteeing Hi-Impact resistance, the PS500 can be used in the most demanding environments.
Specifications
Measuring Ranges
CO | 0 – 1000ppm | |
O2 | 0-25% | |
CO2 | 0 – 5% VOL | |
Dual Toxic CO / H2S | 0 – 1000ppm (CO) 0 – 100ppm (H2S) | |
H2S | 0 – 100ppm | |
LEL | 0 – 100% LEL |
**15 plug-and-play smart sensors to choose from (please refer to datasheet)**
Certification
IEC | EEx iad IIC T3/T4 |
ATEX | Ex II 2 G EEx iad IIC T3/T4 |
UL913 | Class I, Div 1, Groups ABCD (excludes NDIR option) |
MED | (0038/YY) – Module B & E |
CE | 0518 |
Alarms
Brilliant visual alarm
360° distinct alarm level
Ultra loud audible alarm, 95 dBA
Physical Properties
Dimensions:
140 x 85 x 45 mm
Weight:
0.4 kg
Environment
Humidity:
0 – 95% RH non-condensing
Power Supply
Alkaline (3 AA):
12 hours’ minimum with pump
Rechargeable (NiMH):
12 hours’ minimum with pump