DM-700-O2

Introduction

Detcon Model Series 700 industrial gas detectors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series 700 intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.

Specifications

Sensor Type : Continuous diffusion/adsorption , 2-electrode electrochemical cell , Plug-in field replaceable Intelligent Type
Sensor Life : 2 1/2 to 3 years typical
Measurement Range : 0-25% Oxygen by volume
Accuracy/Repeatability : ±1% FS
Response/Clearing Time : T90 ≤ 10 seconds
Span Drift : <5% of signal per year (in first two years)
Outputs : Linear 4-20 mA DC , RS-485 MODBUS-RTU


Electrical Classification
Explosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIC T4 Gb (Tamb = -40°C to +50°C)
Ingress Protection : NEMA 4X, IP66


Safety Approvals
CCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508


Warranty
Plug-in Cell - 2 years; Transmitter - 2 Years 

 

Operating Temperature Range : -40°F to +122°F; -40°C to +50°C
Storage Temperature Range : -40°F to +122°F; -40°C to +50°C
Operating Humidity Range : 0-99% RH non-condensing
Operating Pressure Range : Atmospheric ±10% 

FP-524D-LEL

Introduction

Model FP-524D is a “Smart” gas detection sensor designed to detect and monitor combustible gas in air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology. 

Model FP-524D features Detcon’s MicroSafe™ intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors dating back more than 20 years. The sensor assembly includes the detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C and D).

Specifications

Sensor Type : Matched-pair catalytic bead

Sensor Life : 3 to 5 years typical
Measurement Range : 0-100% LEL (lower explosive limit)
Accuracy/Repeatability : ±3% 0-50% LEL , ±5% 50-100% LEL
Response/Clearing Time : T50 <10 seconds; T90 <30 seconds
Zero Drift : <5% per year
Outputs : Linear 4-20 mA DC , HART (optional)


Electrical Classification
Explosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C)
Class I, Zone 1, Group IIB+H2
Performance Approvals
CSA C22.2 #152-M1984, ISA 12.13.01-2003
Safety Approvals
CSA/NRTL (US OSHA Certified)
Ingress Protection : NEMA 4X, IP66


Warranty
Sensor: 2 year warranty
Transmitter: 2 year warranty 

 

Operating Temperature Range : -40°F to +167°F; -40°C to +75°C
Storage Temperature Range : -40°F to +167°F; -40°C to +75°C
Operating Humidity Range : 5-100% RH non-condensing
Operating Pressure Range : Atmospheric ±10% 

TP-524D-H2S

Introduction

Model TP-524D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidityperformance. 

Model TP-524D is equipped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty.

Specifications

Sensor Type : Continuous diffusion/adsorption , CHEMFET Solid State Metal Oxide Semiconductor
Sensor Life : 5 to 10 years typical
Measurement Range : 0-20 ppm, 0-50 ppm, 0-100 ppm
Accuracy/Repeatability : ±10% of reading or ±2 ppm (greater of )
Response/Clearing Time : T50 <30 seconds; T80 <60 seconds
Outputs : Linear 4-20 mA DC , HART (optional)


Electrical Classification
Explosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C)
Class I, Zone 1, Group IIB+H2
FM
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +60°C)
ATEX
EEx d IIB+H2 T4 (Tamb = -40°C to +60°C)
Performance Approvals
ISA 92.0.01 Part I-1998;
H2S Performance Requirements
Safety Approvals
CCSAUS CSA/NRTL (US OSHA Certified)
FM
ATEX
CE Marking
Ingress Protection : NEMA 4X, IP66


Warranty
Plug-in detector - 10 year conditional
Transmitter - 2 Years 

 

Operating Temperature Range : -40°F to +167°F; -40°C to +75°C
Storage Temperature Range : -31°F to +131°F; -35°C to +55°C
Operating Humidity Range : 5-100% RH non-condensing
Operating Pressure Range : Atmospheric ±10% 

DM-100 Series

Introduction

DM-100-O2 Oxygen Sensor Assembly
DM-100-C2H2 Acetylene Sensor Assembly
DM-102-NH3 Ammonia Sensor Assembly
DM-100-AsH3 Arsine Sensor Assembly
DM-100-Br2 Bromine Sensor Assembly
DM-100-C4H6 Butadiene Sensor Assembly
DM-100-CO Carbon Monoxide Sensor Assembly
DM-100-CL2 Chlorine Sensor Assembly
DM-101-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm)
DM-100-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm)
DM-100-B2H6 Diborane Sensor Assembly
DM-100-C2H5OH Ethanol Sensor Assembly
DM-100-C2H5SH Ethyl Mercaptans Sensor Assembly
DM-100-C2H4 Ethylene Sensor Assembly
DM-100-C2H4O Ethylene Oxide Sensor Assembly
DM-100-F2 Fluorine Sensor Assembly
DM-100-CH2O Formaldehyde Sensor Assembly
DM-100-GeH4 Germane Sensor Assembly
DM-100-N2H4 Hydrazine Sensor Assembly
DM-100-H2 Hydrogen Sensor Assembly (ppm Range)
DM-101-H2 Hydrogen Sensor Assembly (4% Range)
DM-102-H2 Hydrogen Sensor Assembly (1% Range)
DM-100-HBr Hydrogen Bromide Sensor Assembly
DM-100-HCL Hydrogen Chloride Sensor Assembly
DM-100-HCN Hydrogen Cyanide Sensor Assembly
DM-100-HF Hydrogen Fluoride Sensor Assembly
DM-100-H2S Hydrogen Sulfide Sensor Assembly
DM-100-CH3OH Methanol Sensor Assembly
DM-100-CH3SH Methyl Mercaptans Sensor Assembly
DM-100-NO Nitric Oxide Sensor Assembly
DM-100-NO2 Nitrogen Dioxide Sensor Assembly
DM-100-O3 Ozone Sensor Assembly
DM-100-PH3 Phosphine Sensor Assembly
DM-100-SiH4 Silane Sensor Assembly
DM-100-SO2 Sulfur Dioxide Sensor Assembly

Specifications

Sensor Type : Continuous diffusion/adsorption , 3-electrode electrochemical cell , Plug-in field replaceable Type

Measurement Range : Various
Accuracy/Repeatability : ±2% FS
Response/Clearing Time : Various
Span Drift : <2% signal loss per month
Outputs : Linear 4-20 mA DC


Electrical Classification
Explosion proof
CSA and US (NRTL)
Class I, Division 1, Groups A, B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d [ib] ib IIC T4 (Tamb = -40°C to +50°C)
II 1 G Ex ia II C T4 (with IS barrier installed)
Ingress Protection : NEMA 4X, IP66


Safety Approvals
CCSAUS
ATEX
CE Marking
Sensor Life/Warranty
Plug-in cell - 2 years; Transmitter - 2 Years 

 

Operating Temperature Range : -40°F to +122°F; -40°C to +50°C
Storage Temperature Range : -31°F to +131°F; -35°C to +55°C (typical)
Operating Humidity Range : 15% to 90% RH non-condensing (continuous) , 5%-100% RH (intermittent)
Operating Pressure Range : Atmospheric ±10% 

<< 1 2